Quality cut to length line supplier: In terms of productivity, poor PQ can cause unscheduled downtime due to equipment malfunctions or system failures. This unpredictability can significantly disrupt operations, leading to lower productivity levels and potential revenue losses. Moreover, poor PQ can lead to diminished energy efficiency. Transformers operating under poor power quality conditions often require more power to function, leading to increased energy consumption and higher operating costs. The excess power demand could also strain the electrical grid, leading to further inefficiencies and disruptions. Additionally, the costs associated with repairing or replacing damaged equipment due to poor power quality can be substantial. There are also indirect costs to consider, such as those associated with investigation and troubleshooting of power quality issues. Read extra info on transformer coil.
Why do transformers use silicon steel sheets as iron cores? Transformers use silicon steel sheets as iron cores because silicon steel sheets have high magnetic permeability and low resistance. In a transformer, the iron core mainly undertakes the role of conducting magnetic flux. Therefore, the magnetic permeability of the iron core is very critical. Silicon steel sheet is a specially treated steel with very high magnetic permeability, can effectively conduct magnetic flux, and can reduce the loss of magnetic flux and eddy current loss. In addition, the transformer will produce electromagnetic induction phenomenon during the working process, which will generate eddy current in the iron core. These eddy currents cause loss of energy and heating of the core, reducing the efficiency of the transformer. The silicon steel sheet has low resistance characteristics, which can reduce eddy current loss and improve the efficiency of the transformer. Therefore, using silicon steel sheet as the material of the transformer core can improve the efficiency of the transformer, reduce energy loss, and reduce heat generation of the transformer, thereby prolonging the service life of the transformer.
Current source inverter has a higher power factor: The current source inverter has a higher power factor, which can achieve higher power factor correction, thereby reducing grid harmonic pollution. However, since a higher power factor requires larger capacitor support, a transformer with a larger capacity needs to be selected to meet the power supply requirements of the capacitor. Current source inverter needs additional power supply: The circuit of current source inverter needs additional power supply to ensure the normal operation of the current loop control. These additional power sources need sufficient capacity to support, so a transformer with a larger capacity needs to be selected to meet the power supply requirements. Therefore, the current source inverter needs a larger transformer capacity to ensure the normal operation of the intermediate inductor, support the power supply of the capacitor and meet the power supply requirements. When selecting a transformer, it needs to be selected according to the actual electrical parameters and performance requirements to ensure the normal operation and stability of the inverter.
CANWIN adheres to the business policy of high -end manufacturing, intelligent equipment + intelligent factory, comprehensively improves the quality of products and the cutting speed and precision, accelerates the transformation of development mode, and promotes the upgrading of industrial structure In terms of new product development, the company relies on the “Guangdong university of technology provincial thin plate processing and cutting technology engineering center”as an innovation platform, continuously trains and introduces technological talents, and provides intellectual support for the company to enhance soft power and rapid development.
Canwin, a electrical equipment manufacturer mainly produces 150 model oil-type transformer core shearing equipment below 1 600KVA, 300 model dry type transformer core shearing equipment below 6300KVA, 400 model special transformer core shearing equipment below 12500KVA and 600 model special transformer core shearing equipment below 63000KVA. 800 model extra transformer core shearing equipment, 1000 model extra transformer core shearing equipment, the type 1250 model CRGsilicon steel CNC slitting machine, and the dry type transformer core under 110KV automatic cutting and laminated processing center, oil transformer core automatic cutting robot automatic lamination processing center, reactor cutting center below 35Kv, 220KV high voltage china transformer equipment tc. Transformer core & transformer coil manufacturing and assembly, including coil windings using copper and silver alloyed or continuously transposed copper cable.Canwin hire famous designer in Europe as our senior consultant, and germany Siemens as our strategic partner. The products have formed 5 series and more than 50 specifications.Canwin is your best choice of electrical equipment suppliers.
Three-dimensional wound core transformer breaks through the traditional triangle plane structure, adopts three-phase symmetric vertical structure, magnetic circuit completely symmetrical three-phase core products, magnetic resistance is greatly reduced, excitation current, no-load loss, is a kind of using traditional materials, but lower operating noise, structure is more compact and efficient energy-saving oil type transformer. Its excellent performance in energy saving and energy saving and environmental protection is in line with China’s energy conservation policy.
The transformer coils are referred to as the primary and secondary windings. When applying AC current to the primary winding of the transformer, the transformer coil creates a pulsing magnetic field. The core of the transformer works to direct the path of the magnetic field between the primary and secondary coils to prevent wasted energy.The machine is a very powerful and versatile machine which can wind a wide range of HV coils for distribution transformers using round and rectangular wires. It is fully automatic with paper strip winding.Winding material lnsulated with an epoxy resin -environmentally friendly.
As a result of mutual inductance, a transformer produces a transformed voltage or current when the magnetic flux produced by one winding (primary winding) links with another winding (secondary winding). There is a magnetic coupling between these two windings, and they are electrically isolated. In addition, magnetic reluctance is also known as opposition to magnetic flux flow. If, for example, the magnetic flux produced by a primary winding passes through air or any nonferrous material in order to reach a secondary winding in a transformer, it would result in a reduction in magnetic flux. Due to the high reluctance of air or nonferrous materials, it will reduce magnetic flux. See more info at canwindg.com
Laser welding machine is an efficient and precise welding method using high energy density laser beam as a heat source. Laser welding is one of the important applications of laser material processing technology. It mainly used for welding thin wall material and low speed in the 1970 s. The welding process is thermal conduction, i.e. the laser radiation heating surface, the surface heat to the internal diffusion through heat conduction, by controlling the width of laser pulse, energy, peak power and repeating frequency, parameters such as melting of components, to form specific molten pool. Because of its unique advantages, it has been successfully used in precision welding of micro and small parts.As one of the best laser welding machine manufacturers in China, Canwin specialized in handheld laser welding machine and wholesale fiber laser welding machine making for over 20 years.
Energy management system, which uniformly allocates and manages the wind energy, photovoltaic, power grid, battery system and distribution system of micro grid, so as to achieve energy efficiency and high-quality energy allocation. The remote cloud platform and mobile terminal can optimize the system through big data analysis, while reversing the relevant information and operation status to the users’ mobile phone. Containerized Energy Storage System is a complete, self-contained battery solution for a large-scale marine energy storage. The batteries and converters, transformer, controls, cooling and auxiliary equipment are pre-assembled in the self-contained unit. Advantages of containerized power systems: customization, scalability, stackable and cost effective.
Connection group label: According to the phase relationship between the primary and secondary windings of the transformer, the transformer windings are connected into various combinations, which are called the connection group of the windings. In order to distinguish different connection groups, the clock notation is often used, that is, the phasor of the line voltage on the high-voltage side is used as the long hand of the clock, fixed at 12, and the phasor of the line voltage on the low-voltage side is used as the short hand of the clock. The number of the short hand indicates the connection group label. For example, Dyn11 indicates that the primary winding is (triangle) connected, and the secondary winding is (star) connected with a center point, and the group number is (11) points.